NCT/UCC MALDI Imaging Unit

Three people in medical attire in a lab with a large device labeled 'rapifleX', one person seated at a computer showing a colorful image on the screen
Figure 1: MALDI imaging instrument. Rapiflex MALDI TOF/TOF Tissuetyper (Bruker Daltonik GmbH) for performing MALDI imaging analysis based on time-of-flight molecular mass detection.
Matrix-associated laser desorption/ionization imaging (MALDI imaging) combines two fields of bioanalytical methods: molecule analysis using time-of-flight mass spectrometry and the macroscopic anatomy of the tissue compartments. Regions of interest (ROI) of diseased tissue defined by pathologists are translated into mass spectra patterns and can be used for subsequent biostatistical analyses of protein, peptide or lipid composition and quantification. In addition to the knowledge gained from differing mass spectra in e.g. tumor versus normal tissue areas, morphologically indistinguishable tumors can be subdivided and analyzed for molecule-dependent heterogeneity through segmentation of mass intensities at a very high resolution (down to 5x5 micrometers).

In addition to the conventional MALDI analysis for routine diagnostics and new approaches, the MALDI Imaging Unit invenstigates bioinformatic workflows and AI based calculation to utilize complex data for faster data visualization.

Two side-by-side tissue sections, one color-coded and one grayscale, with a scale bar below
Figure 2: Visualization of mass spectra pattern on tissue slides via segmentation. A pancreatic tumor sample was analyzed by MALDI imaging. Left side: Visualization of mass spectra as segmentation map based on trained regions of interest of specified tissue compartments. Right side: Grayscale image scan of the same tissue. Red: pancreatic tissue, orange: tumor tissue, dark red: stroma, yellow: fatty tissue, pink: lymph node, lilac/rose: background.

 

Research focus

  • Tumor classification of rare tumor types
  • Segmentation of (intra-)tumor heterogeneity
  • Lipid, protein and peptide mass spectra identification of novel tumor subtypes
  • Generation of an ever-growing database of tumor vs normal tissue mass spec data
  • MALDI segmentation pipelines based on deep learning
  • 3D MALDI imaging approaches

Sample types for MALDI imaging

  • Fresh frozen tissue
  • Formalin-fixed paraffin-embedded (FFPE) tissue
  • Samples with and without on-slide enzymatic digestion
  • Embedded organoids, spheres or cell culture blocks

Technical information

  • Positive and negative flight mode detected by linear or reflector detector
  • Mass range (positive mode e.g. peptides: 600-3200 m/z, proteins 1000-500,000 m/z)
  • Scan range: 5x5µm to 150x150µm resulting field size
  • Automated batch run option
  • External calibration and quality controls provided
  • Big data storage
Graph showing multiple narrow peaks representing relative intensity versus m/z values
Figure 3: Mass spectra of tumor region. Example of one mass spectra pattern in a range of 600-3200 m/z of a tumor region (FFPE sample).

Coordination

Dr. rer. med. Pia Hönscheid
Group leader
Email: pia.hoenscheid(at)ukdd.de
Phone: +49 (0)351 458 13038

Director

Prof. Dr. med. Gustavo Baretton
Director of Institute of Pathology Dresden
Email: Gustavo.Baretton(at)ukdd.de
Phone: +49 (0)351 458 3000

Team

Christian Sperling
Medical Technical Assistant
Email: Christian.Sperling(at)ukdd.de
Phone: +49 (0)351 458 13009

Maxime le Floch  
MD Student
Email: maxime.lefloch(at)medforum-dresden.de   
Phone: +49 (0)351 458 3009

Maximilian Weiss
Physician in further education
Email: Maximilian.Weiss(at)ukdd.de 
Phone: +49 (0)351 458 5266